The default search directory (nominally /usr/local/lib) can be overriden
by setting the environment variable CAD_ROOT to the appropriate
directory prior to running IRSIM (i.e. setenv CAD_ROOT /cad/lib).
IRSIM first processes the files named on the command line, then (assuming
the exit command has not been processed) accepts commands from the user,
executing each command before reading the next.
File names NOT beginning with a '-' are assumed to be sim files (see sim(5)),
note that this version does not require to run the sim files through
presim. These files are read and added to the network
database. There is only a single name space for nodes, so
references to node "A" in different network files all refer to the same
node. While this feature allows one to modularize a large circuit into
several network files, care must be taken to ensure that no unwanted
node merges happen due to an unfortunate clash in names.
File names prefaced with a '-' are assumed to be command files:
text files which contain command lines to be processed in the normal
fashion. These files are processed line by line; when an end-of-file
is encountered, processing continues with the next file. After all the
command files have been processed, and if an "exit" command has not
terminated the simulation run, IRSIM will accept further commands from
the user, prompting for each one like so:
- irsim>
-
The
hist_file
is the name of a file created with the
dumph
command (see below). If it is present, IRSIM will initilize the network
to the state saved in that file. This file is different from
the ones created with the ">" command since it saves the state of every node
for all times, including any pending events.
This version supports changes to the network through the
update
command. Also, the capability to incrementally re-simulate the network
up to the current time is provided by the
isim
command.
COMMAND SUMMARY
-
- @ filename
-
take commands from command file
- ? wnode...
-
print info about node's source/drain connections
- ! wnode...
-
print info about node's gate connections
- < filename
-
restore network state from file
- > filename
-
write current network state to file
- << filename
-
same as "<" but restores inputs too
- | comment...
-
comment line
- activity from [to]
-
graph circuit activity in time interval
- ana wnode...
-
display nodes in analyzer window
- analyzer wnode...
-
display nodes in analyzer window
- assert wnode [m] val
-
assert that wnode equals value
- assertWhen nodeT valT node val
-
assert when a condition is met
- back [time]
-
move back to time
- c [n]
-
simulate for n clock cycles (default:1)
- changes from [to]
-
print nodes that changed in time interval
- clock [node [val]]
-
define value sequence for clock node
- clear
-
clear analyzer window (remove signals)
- d [wnode]...
-
print display list or specified node(s)
- debug [debug_level...]
-
set debug level (default: off)
- decay [n]
-
set charge decay time (0 => no decay)
- display [arg]...
-
control what gets displayed when
- dumph filename...
-
write net history to file
- hist [on|off]
-
turn history on or off
- exit [status]
-
return to system
- flush [time]
-
flush out history up to time (default: now)
- h wnode...
-
make node logic high (1) input
- has_coords
-
print YES if transistor coordinates are available
- inputs
-
print current list of input nodes
- ires [n]
-
set incremental resolution to n ns
- isim [filename]
-
incrementally resimulate changes form filename
- l wnode...
-
make node logic low (0) input
- logfile [filename]
-
start/stop log file
- model [name]
-
set simulation model to name
- p
-
step clock one simulation step (phase)
- path wnode...
-
display critical path for last transition of a node
- powlogfile [filename]
-
start/stop power logfile
- powtrace -[node]...
-
start/stop power tracing of specified node(s)/vector(s)
- powstep
-
toggle the display of power estimate for each timestep
- print comment...
-
print specified text
- printp
-
print a list of all pending events
- printx
-
print all undefined (X) nodes
- q
-
terminate input from current stream
- R [n]
-
simulate for n cycles (default:longest sequence)
- readh filename
-
read history from filename
- relax
-
attempt to instantaneously resolve undefined states
- report[level]
-
set/reset reporting of decay events
- s [n]
-
simulate for n ns. (default: stepsize)
- stepsize [n]
-
set simulation step size to n ns.
- set vector value
-
assign value to vector
- setlog[file|off]
-
log net changes to file (off -> no log)
- setpath
-
set search path for cmd files
- stats
-
print event statistics
- sumcap
-
print out the sum of the capacitance of all nodes
- t [-]wnode...
-
start/stop tracing of specified nodes
- tcap
-
print list of shorted transistors
- time [command]
-
print resource utilization summary
- until wnode [mask] value count
-
delayed assert based on the clock count.
- u wnode...
-
make node undefined (X) input
- unitdelay [n]
-
force transitions to take n ns. (0 disables)
- update filename
-
read net changes from file
- V [node [value...]]
-
define sequence of inputs for a node
- vector label node...
-
define bit vector
- vsupply voltage
-
set supply voltage for calculating power (default 5V)
- w [-]wnode...
-
add/delete nodes from display list
- wnet [filename]
-
write network to file
- x wnode...
-
remove node from input lists
- Xdisplay [host:n]
-
set/show X display (for analyzer)
- COMMAND DESCRIPTIONS
-
Commands have the following simple syntax:
- cmd arg1 arg2 ... argn <newline>
-
where
cmd
specifies the command to be performed and the argi are arguments
to that command. The arguments are separated by spaces (or tabs) and the
command is terminated by a
<newline>.
If
cmd
is not one of the built-in commands documented below, IRSIM appends
".cmd" to the command name and tries to open that file as a command file
(see "@" command). Thus the command
"foo" has the same effect as "@ foo.cmd".
Notation:
- ...
-
indicates zero or more repetitions
- [ ]
-
enclosed arguments are optional
- node
-
name of node or vector in network
- wnode
-
name of node or vector in network, can include '*' wildcard
which matches any sequence of zero or more characters. The pair of
characters '{' and '}' denote iteration over the limits
enclosed by it, for example:
name{1:10}
will expand into
name1, name2 ... name10.
A 3rd optional argument sets the stride, for example:
name{1:10:2}
will expand into
name1, name3, ... name7, name9.
- | comment...
-
Lines beginning with vertical bar are treated as comments and
ignored -- useful for comments or temporarily disabling certain
commands in a command file.
Most commands take one or more node names as arguments. Whenever a node
name is acceptible in a command line, one can also use the name of a bit
vector. In this case, the command will be applied to each node of the
vector (the "t" and "d" treat vectors specially, see below).
- vector label node...
-
Define a bit vector named "label" which includes the specified
nodes. If you redefine a bit vector, any special attributes of
the old vector (e.g., being on the display or trace list) are
lost. Wild cards are not accepted in the list of
node names since you would have no control over the order in
which matching nodes would appear in the vector.
The simulator performs most commands silently. To find out what's
happened you can use one of the following commands to examine the state
of the network and/or the simulator.
- set vector value
-
Assign value to
vector.
For example, the following sequence of commands:
-
vector BUS bit.1 bit.2 bit.3
set BUS 01x
-
The first command will define
BUS
to be a vector composed of nodes
bit.1, bit.2,
and
bit.3.
The second command will assign the following values:
-
bit.1 = 0
-
bit.2 = 1
-
bit.3 = X
-
- Value can be any sequence of [0,1,h,H,l,L,x,X], and must be of the same
length as the bit vector itself.
- d [wnode]...
-
Display. Without arguments displays the values all nodes and bit
vectors
currently on the display list (see
w
command). With
arguments, only displays the nodes or bit vectors specified. See also
the "display" command if you wish to have the display list printed out
automatically at the end of certain simulation commands.
- w [-]wnode...
-
Watch/unwatch one or more nodes. Whenever a "d"
command is given, each watched node will displayed like so:
-
node1=0 node2=X ...
-
To remove a node from the watched list, preface its name with a '-'.
If wnode is the name of a bit vector, the values of the nodes which
make up the vector will be displayed as follows:
-
label=010100
-
where the first 0 is the value of first node in the list, the first 1
the value of the second node, etc.
- assert wnode [mask] value
-
Assert that the boolean value of the node or vector
wnode
is value. If the comparison fails, an error message is printed.
If
mask
is given then only those bits corresponding to zero bits in
mask
take part in the comparison, any character other than 0 will skip
that bit.
The format of the error message is the following:
-
(tty, 3): assertion failed on 'name' 10X10 (1010X)
-
- Where
name
is the name of the vector, followed by the actual value and the
expected value enclosed in parenthesis. If a
mask
is specified, then bits that were not compared are printed as '-'.
- until wnode [mask] value count
-
Acts just like the assert command except it requires an
additional argument <count> which is the max number of clock cycles
to run. Instead of just testing the current state, like assert, until
tests for true and if false it runs clock cycles until condition becomes
true or count runs out.
- ana wnode...
-
This is a shorthand for the analyzer command (described below).
- analyzer wnode...
-
Add the specified node(s)/vector(s) to the analyzer display list (see
irsim-analyzer(3) for a detailed explanation). If the analyzer window does
not exist, it will be created. If no arguments are given and the
analyzer window already exists, nothing happens.
- Xdisplay [host:display]
-
You must be able to connect to an X-server to start the analyzer. If
you haven't set up the
DISPLAY
environment variable properly, the analyzer command may fail. If
this is the case you can use the
Xdisplay
command to set it from within the simulator.
With no arguments, the name of the current X-server will be printed.
- clear
-
Removes all nodes and vectors from the analyzer window. This command is
most useful in command scripts for switching between different signals
being displayed on the analyzer.
"?" and "!" allow the user to go both backwards and forwards
through the network. This is a useful debugging aid.
- ? wnode...
-
Prints a synopsis of the named nodes including their current values
and the state of all transistors that affect the value of these nodes.
This is the most common way of wandering through the network in
search of what went wrong.
The output from the command
? out
looks like
-
-
- out=0 (vl=0.3 vh=0.8) (0.100 pf) is computed from:
-
- n-channel phi2=0 out=0 in=0 [1.0e+04, 1.3e+04, 8.7e+03]
-
- pulled down by (a=1 b=1) [1.0e+04, 1.3e+04, 8.8e+03]
-
- pulled up [4.0e+04, 7.4e+04, 4.0e+04]
The first line gives the node's name and current value, its low and
high logic thresholds, user-specifed low-to-high and high-to-low
propagation delays if present, and its capacitance if nonzero.
Succeeding lines list the transistor whose sources or drains connect to
this node: the transistor type ("pulled down" is an n-channel transistor
connected to
gnd, "pulled up" is a depletion pullup or p-channel transistor connected
to vdd), the values of the gate,
source,
and drain nodes, and the modeling resistances. Simple chains
of transistors with the same implant type are collapsed by the
-s
option into a single transistor with a "compound" gate; compound gates appear
as a parenthesized list of nodes (e.g., the pulldown shown above). The
three resistance values
-- static, dynamic high, dynamic low -- are
given in Kilo-ohms.
Finally, any pending events for a node are
listed after the electrical information.
- ! wnode...
-
For each node in the argument list, print a list of transistors
controlled by that node.
- tcap
-
Prints a list of all transistors with their source/drain shorted together or
whose source/drain are connected to the power supplies. These transistors
will have no effect on the simulation other than their gate capacitance load.
Although transistors connected across the power supplies are real
design errors, the simulator does not complain about them.
Any node can be made an input -- the simulator will not change an input node's
value until it is released. Usually on specific nodes -- inputs to the
circuit -- are manipulated using the commands below, but you can fool with
a subcircuit by forcing values on internal nodes just as easily.
- h wnode...
-
Force each node on the argument list to be a high (1) input. Overrides
previous input commands if necessary.
- l wnode...
-
Like "h" except forces nodes to be a low (0) input.
- u wnode...
-
Like "h" except forces nodes to be a undefined (X) input.
- x wnode...
-
Removes nodes from whatever input list they happen to be on. The
next simulation step will determine the correct node value
from the surrounding circuit. This is the default state of most nodes.
Note that this does not force nodes to have an "X" value -- it simply
removes them from the input lists.
- inputs
-
prints the high, low, and undefined input lists.
It is possible to define a sequence of values for a node, and then
cycle the circuit as many times as necessary to input each value and simulate
the network. A similar mechanism is used to define the sequence of values
each clock node goes through during a single cycle.
Each value is a list of characters (with no intervening blanks) chosen from
the following:
-
- 1, h, H
-
logic high (1)
- 0, l, L
-
logic low (0)
- u, U
-
undefined (X)
- x, X
-
remove node from input lists
Presumably the length of the character list is the same as the size of
the node/vector to which it will be assigned. Blanks (spaces and tabs)
are used to separate values in a sequence. The sequence is used one
value at a time, left to right. If more values are needed than supplied
by the sequence, IRSIM just restarts the sequence again.
- V [node [value...]]
-
Define a vector of inputs for a node. After each cycle of an "R"
command, the node is set to the next value specified in the
sequence.
-
With no arguments, clears all input sequences (does not affect
clock sequences however). With one argument, "node", clears any
input sequences for that node/vector.
- clock [node [value...]]
-
Define a phase of the clock. Each cycle, each node specified by a
clock command must run through its respective values. For example,
-
clock phi1 1 0 0 0
-
clock phi2 0 0 1 0
-
- defines a simple 4-phase clock using nodes
phi1
and
phi2.
Alternatively one could have issued the following commands:
-
vector clk phi1 phi2
-
clock clk 10 00 01 00
- With no arguments, clears all clock sequences. With one argument,
"node", clears any clock sequences for that node/vector.
After input values have been established, their effect can be propagated
through the network with the following commands. The basic simulated time
unit is 0.1ns; all event times are quantized into basic time units. A
simulation step continues until
stepsize
ns. have elapsed, and any
events scheduled for that interval are processed. It is possible to build
circuits which oscillate -- if the period of oscillation is zero,
the simulation command will not return. If this seems to be the case, you
can hit
<ctrl-C>
to return to the command interpreter. Note that if you do this while input
is being taken from a file, the simulator will bring you to the top level
interpreter, aborting all pending input from any command files.
When using the linear model (see the "model" command) transition times
are estimated using an RC time constant calculated from the surrounding
circuit. When using the switch model, transitions are scheduled with
unit delay. These calculations can be overridden for a node by setting
its tplh and tphl parameters which will then be used to determine the time
for a transition.
- s [n]
-
Simulation step. Propogates new values for the inputs through the
network, returns when n (default: stepsize) ns. have passed.
If
n
is specified, it will temporarily override the
stepsize
value. Unlike
previous versions, this value is NOT remembered as the default value for the
stepsize
parameter. If the display mode is "automatic", the current
display list is printed out on the completion of this command (see
"display" command).
- c [n]
-
Cycle
n
times (default: 1) through the clock, as defined by the
"clock" command. Each phase of the clock lasts
stepsize
ns.
If the display mode is "automatic", the current display list is
printed out on the completion of this command (see "display" command).
- p
-
Step the clock through one phase (or simulation step). For example,
if the clock is defined as above
-
clock phi1 1 0 0 0
-
clock phi2 0 0 1 0
-
- then "p" will set phi1 to 1 and phi2 to 0, and then propagate the
effects for one simulation step. The next time "p" is issued, phi1
and phi2 will both be set to 0, and the effects propagated, and so on.
If the "c" command is issued after "p" has been used, the effect
will be to step through the next 4 phases from where the "p" command
left off.
- R [n]
-
Run the simulator through
n
cycles (see the "c" command). If
n
is not present make the run as long as the longest sequence. If display
mode is automatic (see "display" command) the display is printed
at the end of each cycle. Each "R" command starts over at the
beginning of the sequence defined for each node.
- back time
-
Move back to the specified time. This command restores circuit state
as of time, effectively
undoing any changes in between. Note that you can not move
past any previously flushed out history (see flush command below)
as the history mechanism is used to restore the network state. This command
can be useful to undo a mistake in the input vectors or to re-simulate the
circuit with a different debug level.
- path wnode...
-
display critical path(s) for last transition of the specified node(s).
The critical path transistions are reported using the following format:
-
node -> value @ time (delta)
-
- where node is the name of the node, value is the value to which
the node transitioned, time is the time at which the transistion
occurred, and delta is the delay through the node since the last
transition. For example:
-
critical path for last transition of Hit_v1:
-
phi1-> 1 @ 2900.0ns , node was an input
-
PC_driver-> 0 @ 2900.4ns (0.4ns)
-
PC_b_q1-> 1 @ 2904.0ns (3.6ns)
-
tagDone_b_v1-> 0 @ 2912.8ns (8.8ns)
-
tagDone1_v1-> 1 @ 2915.3ns (2.5ns)
-
tagDone1_b_v1-> 0 @ 2916.0ns (0.7ns)
-
tagDone_v1-> 1 @ 2918.4ns (2.4ns)
-
tagCmp_b_v1-> 0 @ 2922.1ns (3.7ns)
-
tagCmp_v1-> 1 @ 2923.0ns (0.9ns)
-
Vbit_b_v1-> 0 @ 2923.2ns (0.2ns)
-
Hit_v1-> 1 @ 2923.5ns (0.3ns)
- activity from_time [to_time]
-
- print histogram showing amount of circuit activity in the specified
time inteval. Actually only shows number of nodes which had their
most recent transition in the interval.
- changes from_time [to_time]
-
print list of nodes which last changed value in the specified
time interval.
- printp
-
print list of all pending events sorted in time. The node associated
with each event and the scheduled time is printed.
- printx
-
print a list of all nodes with undefined (X) values.
Using the trace command, it is possible to get more detail about what's
happening to a particular node. Much of what is said below is described
in much more detail in "Logic-level Simulation for VLSI Circuits" by
Chris Terman, available from Kluwer Academic Press. When a node is traced,
the simulator reports each change in the node's value:
-
[event #100] node out.1: 0 -> 1 @ 407.6ns
The event index is incremented for each event that is processed. The
transition is reported as
-
old value -> new value @ report time
Note that since the time the event is processed may differ from the
event's report time, the report time for successive events may not be
strictly increasing.
Depending on the debug level (see the "debug" command) each
calculation of a traced node's value is reported:
-
[event #99] node clk: 0 -> 1 @ 400.2ns
-
final_value( Load ) V=[0.00, 0.04] => 0
-
..compute_tau( Load )
-
{Rmin=2.2K Rdom=2.2K Rmax=2.2K} {Ca=0.06 Cd=0.17}
-
tauA=0.1 tauD=0.4 ns
-
[event #99: clk->1] transition for Load: 1 -> 0 (tau=0.5ns, delay=0.6ns)
In this example, a calculation for node
Load
is reported. The calculation
was caused by event 99 in which node clk went to 1. When using the
linear model (as in this example) the report shows
-
current value -> final value
The second line displays information regarding the final value
(or dc) analysis for node "Load"; the minimun and maximum voltages
as well as the final logical value (0 in this case).
The next three lines display timing analysis information used to estimate
the delays. The meaning of the variables displayed can be found Chu's
thesis: "Improved Models for Switch-Level Simulation".
When the final value is reported as "D", the node is not connected to an
input and may be scheduled to decay from its current value to X at some later
time (see the "decay" command).
"tau" is the calculated transition time constant, "delta"
is when any consequences of the event will be
computed; the difference in the two times is how IRSIM accounts for the shape
of the transition waveform on subsequent stages (see reference given above for
more details). The middle lines of the report indicate the Thevenin and
capacitance parameters of the surrounding networks, i.e., the parameters on
which the transition calculations are based.
- debug [ev dc tau taup tw spk][off][all]
-
Set debugging level. Useful for debugging simulator and/or circuit
at various levels of the computation. The meaning of the various
debug levels is as follows:
-
- ev
-
display event enqueueing and dequeueing.
- dc
-
display dc calculation information.
- tau
-
display time constant (timing) calculation.
- taup
-
display second time constant (timing) calculation.
- tw
-
display network parameters for each stage of the tree walk, this
applies to dc, tau, and taup. This level of debugging
detail is usually needed only when debugging the simulator.
- spk
-
displays spike analysis information.
- all
-
This is a shorthand for specifying all of the above.
- off
-
This turns off all debugging information.
-
If a debug switch is on then during a simulation step, each time a watched
node is encounted in some event, that fact is indicated to the user
along with some event info. If a node keeps appearing in this prinout,
chances are that its value is oscillating. Vice versa, if your circuit
never settles (ie., it oscillates) , you can use the "debug" and
"t" commands to find the node(s) that are causing the problem.
Without any arguments, the debug command prints the current debug level.
- t [-]wnode...
-
set trace flag for node. Enables the various printouts described
above.
Prefacing the node name with '-' clear its trace flag.
If "wnode" is the name of a vector, whenever any node of that vector
changes value, the current time and the values of all traced vectors
is printed. This feature is useful for watching the relative
arrival times of values at nodes in an output vector.
System interface commands:
- > filename
-
Write current state of each node into specified file. Useful for
making a breakpoint in your simulation run. Only stores values so
isn't really useful to "dump" a run for later use, i.e., the current
input lists, pending events, etc. are NOT saved in the state file.
- < filename
-
Read from specified file, reinitializing the value of each node as
directed. Note that network must already exist and be identical to the
network used to create the dump file with the ">" command. These
state saving commands are really provided so that complicated
initializing sequences need only be simulated once.
- << filename
-
Same as "<" command, except that this command will restore the
input
status of the nodes as well. It does not, however, restore pending
events.
- dumph [filename]
-
Write the history of the simulation to the specified file, that is; all
transistions since time = 0. The resulting file is a machine-independent
binary file, and contains all the required information to continue
simulation at the time the dump takes place. If the filename isn't
specified, it
will be constructed by taking the name of the sim_file (from the command
line) and appending ".hist" to it.
- readh filename
-
Read the specified history-dump file into the current network. This
command will restore the state of the circuit to that of the dump file,
overwriting the current state.
- flush [time]
-
If memory consumption due to history maintanance becomes prohibitive, this
command can be used to free the memory consumed by the history up to the
time specified. With no arguments, all history up to the current
point in the simulation is freed. Flushing out the history may invalidate
an incremental simulation and the portions flushed will no longer appear
in the analyzer window.
- setpath [path...]
-
Set the search-path for command files. Path should be a sequence
of directories to be searched for ".cmd" files, "." meaning the current
directory. For eaxmple:
-
setpath . /usr/me/rsim/cmds /cad/lib/cmds
-
- With no arguments, it will print the current search-path. Initially this
is just ".".
- print text...
-
Simply prints the text on the user's console. Useful for keeping
user posted of progress through a long command file.
- logfile [filename]
-
Create a logfile with the specified name, closing current log file if
any; if no argument, just close current logfile. All output which
appears on user's console will also be placed in the logfile. Output
to the logfile is cleverly formatted so that logfiles themselves can
serve as command files.
- setlog [filename | off]
-
Record all net changes, as well as resulting error messages, to the
specified file (see "update" command). Net changes are always
appended to the log-file, preceding each sequence of changes by the
current date. If the argument is
off
then net-changes will not be logged. With no arguments, the name of the
current log-file is printed.
The default is to always record net changes; if no filename is specified
(using the "setlog" command) the default filename
irsim_changes.log
will be used. The log-files are formatted so that log-files may
themselves be used as net-change files.
- wnet [filename]
-
Write the current network to the specified file. If the filename isn't
specified, it will be constructed by taking the name of the sim_file
(from the command line) and appending ".inet" to it. The resulting file
can be used in a future simulation run, as if it were a sim file. The file
produced is a machine independent binary file, which is typically about 1/3
the size of the sim file and about 8 times faster to load.
- time [command]
-
With no argument, a summary of time used by the simulator is printed.
If arguments are given the specified command is timed and a time summary
is printed when the command completes.
The format of the time summary is Uu Ss E P% M, where:
-
U => User time in seconds
-
S => System time in seconds
-
E => Elapsed time, minutes:seconds
-
P => Percentage of CPU time (((U + S)/E) * 100)
-
M => Median text, data, and stack size use
- q
-
- Terminate current input stream. If this is typed at top level, the
simulator will exit back to the system; otherwise, input reverts to
the previous input stream.
- exit [n]
-
Exit to system,
n
is the reported status (default: 0).
Simulator parameters are set with the following commands. With no arguments,
each of the commands simply prints the current value of the parameter.
- decay [n]
-
Set decay parameter to
n
ns. (default: 0). If non-zero, it tells the number of ns. it
takes for charge on a node to decay to X. A value of 0 implies
no decay at all. You cannot specify this parameters separately
for each node, but this turns out not to be a problem. See "report"
command.
- display [-][cmdfile][automatic]
-
set/reset the display modes, which are
-
- cmdfile
-
commands executed from command files are displayed to user before
executing. The default is
cmdfile = OFF.
- automatic
-
print out current display list (see "d" command) after
completion of "s" or "c" command. The default is
automatic = ON.
-
Prefacing the previous commands with a "-" turns off that display option.
- model [name]
-
Set simulation model to one of the following:
-
- switch
-
Model transistors as voltage controlled switches. This model uses interval
logic levels, without accounting for transistor resistances, so circuits
with fighting
transistors may not be accuratelly modelled. Delays may not reflect the
true
speed of the circuit as well.
- linear
-
Model transistors as a resistor in series with a voltage controlled switch.
This model uses a single-time-constant computed from the resulting RC
network and uses a two-time-constant model to analyze charge sharing
and spikes.
-
The default is the
linear
model.
You can change the simulation model at any time -- even with events
pending -- as only new calculations are affected.
Without arguments, this command prints the current model name.
- report [level]
-
When level is nonzero, report all nodes which are set to X because of charge
decay, regardless on whether they are being traced. Setting
level to zero disables reporting, but not
the decay itself (see "decay" command).
- stepsize [n]
-
Specify duration of simulation step or clock phase.
n is specified
in ns. (nanoseconds). Floating point numbers with up to 1 digit past
the decimal point are
allowed. Further decimals are trucated (i.e. 10.299 == 10.2).
- unitdelay [n]
-
When nonzero, force all transitions to take
n
ns. Setting
the parameter to zero disables this feature. The resolution is the same
as for the "stepsize" command.
- stats
-
Print event statitistics, as follows:
-
changes = 26077
-
punts (cns) = 208 (34)
-
punts = 0.79%, cons_punted = 16.35%
-
nevents = 28012; evaluations = 27972
-
- Where changes is the total number of transistions recorded, punts
is the number of punted events, (cns) is the number of consecutive
punted events (a punted event that punted another event). The penultimate
line shows the percentage of punted events with respect to the total number
of events, and the percentage of consecutive punted events with respect
to the number of punted events. The last line shows the total number of
events (nevents) and the number of net evaluations.
Incremental simulation commands:
Irsim
supports incremental changes to the network and resimulation of the resulting
network. This is done incrementally so that only the nodes affected by the
changes, either directly or indirectly, are re-evaluated.
- update filename
-
Read net-change tokens from the specified file. The following net-change
commands are available:
-
- add
-
type gate source drain length width [area]
- delete
-
type gate source drain length width [area]
- move
-
type gate source drain length width [area] g s d
- cap
-
node value
- N
-
node metal-area poly-area diff-area diff-perim
- M
-
node M2A M2P MA MP PA PP DA DP PDA PDP
- thresh
-
node low high
- Delay
-
node tplh tphl
-
For a detailed dscription of this file see netchange(5). Note that this
is an experimental interface and is likely to change in the future.
-
Note that this command doesn't resimulate the circuit so that it may leave the
network in an inconsistent state. Usually this command will be followed by an
isim
command (see below), if that is not the case then it's up to the user to
initilize the state of the circuit. This command exists only for historical
reasons and will probably disappear in the future. It's use is discouraged.
- isim [filename]
-
Read net-change tokens from the specified file (see netchange(5)) and
incrementally resimulate the circuit up to the current simulation
time (not supported yet).
- ires n
-
The incremental algorithm keeps track of nodes deviating from their past
behavior as recorded in the network history. During resimulation, a node
is considered to deviate from its history if it's new state is found to be
different within
n
ns of its previous state. This command allows for changing the incremental
resolution. With no arguments, it will print the current resolution. The
default resolution is 0 ns.
- powlogfile [filename]
-
Opens filename for writting nodal transition reports. The format of
the report is the same you get when you trace a node normaly.
With no arguments powlogfile just closes the opened logfile and prints
out a power dissipation summary. Nodal transitions in inputs are
not
included in the transition count.
- powtrace [[-]node...]
-
The syntax of this command is the same as the normal
t
(trace) command.
If you want to trace and report power dissipation for all the nodes
just use powtrace *. Use powtrace
-node
if you want to exclude some nodes.
- powstep
-
Toggles whether dynamic power estimation is displayed after each
timestep. The ynamic power displayed will only be for the nodes that
have been selected using the
powtrace
command.
- vsupply voltage
-
Sets the
V
variable for use in the
P=CV^2/(2t)
expression where
C
is capacitance switched, and
t
is the timestep. The default value for vsupply is 5.0 Volts.
- sumcap
-
Gives a sum of
all
nodal capcitances,
not
just those selected with
the
powtrace
command.
SEE ALSO
presim(1) (now obsolete)
rsim(1)
irsim-analyzer(3)
sim(5)
netchange(5)
Index
- NAME
-
- SYNOPSIS
-
- DESCRIPTION
-
- COMMAND SUMMARY
-
- SEE ALSO
-
This document was created by
man2html,
using the manual pages.
Time: 17:43:48 GMT, October 24, 2006